Please read our Legal Disclaimer before executing any steps on this article
Overview
Applicable Errors:
1213
Error Description:
Network Cable is disconnected or bus is off (network not connected)
Possible Remedy:
- Check condition of serial bus cable and verify the cable is connected on all networked devices.
- Verify Power supply for network is operating correctly (on applicable serial network cards)
- Confirm configuration of IO expansion card (on applicable serial network cards) using the RC7M options manual (link to manuals below)
- Confirm IO parameter settings and FieldBus parameter settings in controller match the settings the machine was originally built with. The settings can be confirmed by checking an older Wincaps III backup project.
- Cycle power on the primary device and RC7 controller.
Tools and Parts Needed
Full sized teaching pendant
Computer with Wincaps III
Next Steps:
- For repair options in the Americas please contact support@densorobotics.com
- For repair options outside of the Americas, please contact your local Denso Service Center.
Owner's Manual Reference
Download RC7 Manual Pack to aid and determine the correct controller configuration. CADs and Manuals - DENSO Robotics
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article