COBOTTA Version Upgrade Function Procedure

Modified on Wed, 9 Oct at 9:20 PM

Please read our Legal Disclaimer before executing any steps on this article. 


Overview

This function upgrades the COBOTTA software.
The upgrade module is available for download at the DENSO website. 

Tools and Parts needed


NOTE:
The version upgrade may not be possible for older versions of WINCAPS III.
To use this function, use the latest version of WINCAPS III.

 

Video Tutorial



Step-by-Step Guide


Enable Version Upgrade (COBOTTA)

Step 1


In the top window, open the "Option" screen as follows:
Top window - [F6 Setting] - [F8 Option]

In the "Option" screen, press the [F8 VersionUp] button.

Step 2

When the following screen is displayed, press [OK]. 


Step 3


When the "version upgrade" option is disabled, the following disabling completion screen is displayed.


NOTE:
The version upgrade enabled state continues until the COBOTTA power is turned OFF or version upgrade is disabled.

For details on disabling version upgrade, refer to "Disabling Version Upgrade" below.


 Version Upgrade Using Version Upgrade Tool (WINCAPSIII) 


Version Upgrade Using Version Upgrade Tool (WINCAPS III) 


Step 1


Log in to WINCPS3 as "Programmer". 


Step 2


In the Tool menu, select "COBOTTA tools" - "Versionup...". 

Step 3


When the following input screen is displayed, enter the items shown in the table below.

When all the input is completed, press [Next]. 

ItemDescription
Target IP addressSpecify the IP address of COBOTTA that uses software to be upgraded.
Upgrade moduleSpecify a save destination on the computer and a file name for the upgrade module downloaded from the DENSO website
Backup projectBack up current data in COBOTTA to the computer.

Specify a project name and save location on the computer.

Step 4


When the following confirmation dialog box is displayed, check the content.
For the content of display, refer to the table below.

If all the content is correct, press [Start]. Version upgrade will begin immediately.

To change the setting content, press [Back]. 


Robot
ItemDescription
Target IP addressIP Address specified in the input screen
Current VersionCurrent software version of COBOTTA
Version after updateSoftware version in the upgrade module.

Backup Project
ItemDescription
Project nameProject name specified in the input screen
Save inSave location specified in the input screen.


Step 5


When version upgrade is started, the screen below comes up and the progress screen is displayed. 


Note:
Version upgrade takes about 10 minutes.

During the version upgrade, DO NOT TURN OFF the power of COBOTTA or disconnect the communication cable unless instructed to do so.

TIP:
Version upgrade is conducted using the following procedure:
1. Project backup: Data currently used in COBOTTA is back up to the computer.
2. Upgrade module transmission: The upgrade module is transmitted to COBOTTA.
3. Module upgrade: The content of the upgrade module is applied to COBOTTA.

Step 6

When the module upgrade is completed, the following end screen is displayed. Turn OFF the power of COBOTTA and turn it ON again.

The upgrade module becomes effective after reboot





Disabling Version Upgrade 

When the power of COBOTTA is turned OFF, version upgrade is disabled.To  disable version upgrade without turning OFF the power, perform the  following procedure: 


Step 1


In the top window, open the "Option" screen as follows:
Top window - [F6 Setting] - [F8 Option]

In the "Option" screen, press the [F8 VersionUp] button.

Step 2


When the following screen is displayed, press [OK]. 

Step 3


When version upgrade is disabled, the following disabling completion screen is displayed.

Press [OK] to go back to the "Option" screen. 


Owner's Manual Reference

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article